Shawarwari Don Amfani da Ƙwararrun Ƙwararrun Ƙwararru A Manyan Filaye
Kayan aikin da aka saba amfani da su na dakin gwaje-gwaje ne waɗanda ke amfani da ƙarfin centrifugal da aka samar ta hanyar jujjuya kawunan kai don raba abubuwa masu yawa daban-daban ko girman barbashi a cikin suspensions ko emulsions.
Laboratory Centrifuges ana amfani da su sosai a fannin likitanci, kayan kwalliya, asibitocin hakori, sinadarai, abinci, magunguna, kare muhalli, hakar ma'adinai, koyarwa & bincike da sauran fannoni.
Siffofin centrifuge (kamar saurin juyawa, ƙarfin bututu guda ɗaya, lokaci, zafin jiki da sauran alamomi) da ake buƙata don sarrafa samfuran a fannoni daban-daban sun bambanta, yana da mahimmanci don zaɓar kayan aikin centrifuge masu dacewa dangane da takamaiman buƙatun gwaji.

Filin Kiwon Lafiya:
Samfuran da aka fi sani da su a fannin likitanci sun haɗa da: samfuran jini, samfuran fitsari, samfuran fecal, da sauransu;
① Centrifugation na jini: yawanci yana buƙatar saurin juyawa na kusan 3000 rpm na kusan mintuna 10.
② Ƙwararren samfurin fitsari: Gabaɗaya yana buƙatar gudun kusan rpm 1800, lokaci kusan mintuna 5.
③ Centrifugation na fecal samfurori: Yawanci yana buƙatar gudun kusan 1,000 rpm na kusan mintuna 10.

Kayan shafawa da asibitocin hakori:
Cosmetology da asibitocin hakori yawanci suna buƙatar raba PRP, PRF da CGF;
① PRP (Platelet-Rich Plasma): Yawanci ana yin shi a saurin gudu daga 300 zuwa 3500 rpm na kusan mintuna 5, galibi ana maimaita shi sau da yawa.
② PRF (Platelet-Rich Fibrin): Yawanci ana yin shi a saurin gudu daga 2000 zuwa 3000 rpm na kusan mintuna 7,guda centrifugation;.
③ CGF (Abubuwan Ci gaba mai Mahimmanci): Ya ƙunshi ɗaruruwan ɗabi'a mai mu'amala mai saurin gudu.

Binciken Biochemical:
①Domin hazo da tarin sel, nuclei, membranes cell, da dai sauransu: Yawanci ana yin ta ta amfani da centrifuges kwance mai saurin sauri.
② Shirye-shirye da tarin ƙwayoyin cuta, gutsuttsura tantanin halitta, manyan gabobin jiki, da sauransu: Sau da yawa ana yin su ta amfani da centrifuges mai sauri.
③ Don rabuwa, tsarkakewa, ganewa da bincike na mitochondria, microsomes, chromosomes, lysosomes, plasmids, manyan kwayoyin kwayoyin nucleic acid, macromolecules na sunadarai, da dai sauransu: Yana buƙatar ultracentrifugation ta amfani da ultracentrifuges.
Masana'antar Abinci:
① Samfurin gwaji na ragowar aiki na centrifugal: yawanci yana buƙatar saurin kusan 4000 rpm, lokacin centrifugation na kusan mintuna 5;
② Cire sitaci daga maganin sitaci, kirim ko rabuwar madara, crystallization daga mahaifiyar giya, da haɓaka tsafta: Yana amfani da centrifuges mara ƙarfi ko ƙarancin zafi.
③ Rarraba spores daga madara: Yawanci ana yin ta ta amfani da centrifuges mai sauri.
Ka tuna, ya kamata a zaɓi samfurin centrifuge daidai bisa ƙayyadaddun aikace-aikacen, nau'in samfurin, da buƙatun gwaji a kowane filin.